One dealership, two structures that move very differently in an earthquake. The two-story showroom, roughly 20,000 square feet, is a light structural steel frame braced with special concentrically braced frames (SCBF), kept open for customers. Beside it, a one-story inventory building of about 50,000 square feet carries cars on its roof. It uses a post-tensioned two-way flat plate, a thin beamless slab, with concrete shear walls to resist the seismic force that comes with all that weight.
Instead of tying a flexible steel frame to a heavy concrete box, a seismic joint separates the two, so each building can respond on its own terms.